Izdelki za lan kabel (8)

OKV z mikrocevmi - OPTIČNI KABLI ZA LAN

OKV z mikrocevmi - OPTIČNI KABLI ZA LAN

Indoor distribution optical cable with free access to optical fibers; the cable contains up to 24 microtubes with optical fibers; each microtube can contain up to 12 optical fibers. The microtubes are loosely laid in Low-Smoke Zero-Halogen sheath. There are two FRP rods as a strength member. Operational temperature for cables is from -10°С to 50°С. Minimum temperature for installation is -30°С. The number of fibers in the cable:up to 288 Tensile force :up to 1,0kN Crushing force:from 200 N/cm Fire-safe:+
OKR z mikrocevmi - OPTIČNI KABLI ZA LAN

OKR z mikrocevmi - OPTIČNI KABLI ZA LAN

Indoor distribution optical cable containing up to 24 microtubes with optical fiber, in each microtubes, up to 12 optical fibers; strength element (high-modulus yarns) is applied over the microtubes, sheath is Low-Smoke Zero-Halogen. Fiberglass bar or steel wire could be used as alternative strength elements. Operational temperature for cables is from -10°С to 50 ° С. Minimum temperature for installation is -10 ° C. The number of fibers in the cable:up to 144 Tensile force :up to -0,5 kN Crushing force:from 30 N/cm Fire-safe:+
OKV - Optični kabli za LAN

OKV - Optični kabli za LAN

Indoor distribution optical cable with free access to optical fibers ( up to 48 fi bers in Tight Buffer, loosely laid in Low-Smoke Zero-Halogen sheath). Strength element is two FRP rods. Operational temperature for cables is from -10°С to 50°С. Minimum temperature for installation is -10°С. The number of fibers in the cable:up to 24 Tensile force :up to 1kN Crushing force:from 200 N/cm Fire-safe:+
OKR - Optični Kabli za LAN

OKR - Optični Kabli za LAN

Indoor distribution optical cable containing up to 12 optical fibers in a Tight Buffer sheath, strength element is high-modulus yarns,outer sheath is Low-Smoke Zero-Halogen. Additional strength elements like fiberglass rod or steel wire can be added. Operational temperature for cables is from -40°С to 50 ° С. Minimum temperature for installation is -10 ° C. The number of fibers in the cable:up to 12 Tensile force :up to -0,5kN Crushing force:from 30 N/cm Fire-safe:+
OKS - Optični Kabli za LAN

OKS - Optični Kabli za LAN

Indoor optical cable contains one optical fiber in Tight Buffer; around it is applied a strength member – high-modulus yarns, with an outer polymer sheath that is fire-retardant in bundle installation; Low-Smoke Zero-Halogen. Operational temperature for cables is from -10°С to 50°С. Minimum temperature for installation is -10°С. The number of fibers in the cable:up to 2 Tensile force :up to 1,0kN Crushing force:from 300 N/cm Fire-safe:+
OKDP z zunanjim ojačevalnim členom - OPTIČNI KABLI ZA LAN

OKDP z zunanjim ojačevalnim členom - OPTIČNI KABLI ZA LAN

Optical cable with an outer strength member made of galvanized steel wire or glass-reinforced plastic rod. Optical fibers are loosely laid in the center of the cable. Sheath is made of fi re-retardant PE, Low-Smoke Zero-Halogen. There are strength members (FRP rods or steel wire) inside the sheath. Operational temperature for outdoor cables is from -60°С to 70°С. Minimum temperature for installation is -30°С. The number of fibers in the cable:up to 4 Tensile force :up to 1,0kN Crushing force:from 300 N/cm Fire-safe:+
OKDP - Optični Kabli za LAN

OKDP - Optični Kabli za LAN

Indoor optical cable; optical fibers are loosely laid in the center of the cable; sheath is made of fire-retardant PE Low-Smoke Zero-Halogen. There are strength members (FRP rods or steel wires) inside the sheath. Operational temperature for outdoor cables is from -60°С to 70°С. Minimum temperature for installation is -30°С. The number of fibers in the cable:up to 4 Tensile force :up to 0,22kN Crushing force:from 300 N/cm Fire-safe:+
OKD - Optični Kabli za LAN

OKD - Optični Kabli za LAN

Indoor optical cable includes two optical fibers in Tight Buffer; a strength member (high-modulus yarns) is applied over them; with outer sheath of polymer that is fi re-retardant in bundle installation Low-Smoke Zero-Halogen. Operational temperature for cables is from -10°С to 50°С. Minimum temperature for installation is -10°С. The number of fibers in the cable:up to 2 Tensile force :up to 1kN Crushing force:from 300 N/cm Fire-safe:+